Monitor manufacturer summary of work experience, monitor the maintenance mainly has the following several aspects:
Monitor usually work continuously for a long time, easy to items within the machine caused by the internal temperature of early ageing and even damaged, so we want to do a good job of cleaning machine of internal and external, to ensure that the machine has good heat dissipation and ventilation.Months check on a host of filter, clean the dust, and at the same time,
also check the surface of the operation panel, display, using anhydrous alcohol to remove the dirt, so as to avoid corrosion of the important components.Every six months to one year is about to open the machine shell, for dust inside the machine.Dust removal at the same time can use "look, smell, touch" intuitive methods, such as inspection on each module, the parts in the machine.Sensor maintenance: due to the nature of the sensor itself and the detection of patients with site often in an active, so it is easy to damage the parts, is an important part of a more expensive.In order to prolong their service life, reduce the treatment cost, we should do a good job for their maintenance.Communicate frequently with the medical staff, guide their correct operation and maintenance of monitor and sensor.Don't fold, drag sensors transmission conductor;Can't fall off, touch sensor probe blood oxygen saturation probe, such as temperature, invasive blood pressure probe.For noninvasive blood pressure cuff, without banding when patients, host at this time cannot be measured, so as not to damage the inflatable balloon.To monitor for long time monitoring, without the need for monitoring the blood oxygen saturation, can be shut down this function by adjusting the system configuration, if the machine have the set or remove blood oxygen saturation and host connection interface, the monitor is generally through the interface to connect the sensor, so as to prolong the service life of the sensor.Easy to pick up on sensor probe sweat, blood and other dirt, in order to avoid corrosion probes and impact measurement, regularly in accordance with the user manual to provide clean probe method.
Monitor in use process is vulnerable to the interference of magnetic field, so don't put mobile phone instrument, so as not to affect the monitoring results.For wire equipment, must not be under pressure in patients with a certain part of the body, so as to avoid damage to the patient's skin.In turn, there is a big movement, sleeping of time don't care more pull wire electrode loss.Because some people for a long time of electrodes, the skin will have certain resistance reaction, such as skin rash, itching, at this time of the patients must inform medical personnel, replacement of paste electrode.But changing the electrode for a little while it is important to note that with stickers to wipe clean, the skin cutin layer to wipe clean.